STEAM DRUM
A steam drum of the boiler is meant for performing the
following.
1. 1. Steam is
purified by the
steam drum internals
which may have
the baffle separators,
cyclone
1.
separators, Chevron separators, demisters / Screen driers.
1. 2. Acts as reservoir and provides the necessary
head for the circulation of water through evaporative
1. surfaces.
1.3.Supplies water for a brief period in the
event of stoppage of water supply.
PARTS OF STEAM DRUM
1. Feed water distributor pipe
2. Safety valve
3. Chemical dosing pipe
4. Continuous Blow down pipe
5. Drum level gauge
6. Cyclone box Chamber
7. Steam Purifier/
demister/ steam Driers
8. Saturated Steam Outlet Pipes
9.Down comer
10 intermittent Blow down Pipe
Feed water distributor pipe
Should distribute the fresh water throughout entire drum
length , so that the fresh water mixes well with boiler water. The feed
distributor should not disturb the drum water level. It should not obstruct the
water entry into the down comer. Otherwise it may lead to circulation failure
of evaporator section. The pipe should
not direct the
cold water to
drum surface. It
may lead to
differential metal
temperature and may
strain the metal. The
feed distributor pipe
shall be flanged
for easy removal
and flanges shall
have proper machining done on the
mating faces. Gaskets are not to be used as they fail over a period.
Safety Valve
The safety valve is to release the excess pressure created
in the drum than the set point of the valve. It should be so located that the
steam when vented out should not disturb the steam drawl by the saturated steam links to super heater. It
should not lead to starvation of Super heater. Hence it is
generally located outside the steam drier unit.
Chemical Dosing Pipe
In order to maintain desirable boiler water chemistry,
suitable chemical is added directly into the drum
water. The chemical is dosed through the chemical
distributing pipe.
Concentrated chemicals are being dosed in the boiler water. Hence the piping shall be of non
corroding material. The piping shall be of stainless steel
construction. The chemical should be well distributed throughout the drum
length. Or else it can be connected to feed water pipe itself so that it helps
for better mixing. The chemical distribution piping should not get choked due
to chemical. The hole diameter shall be 6 mm. Holes shall be pitched at 300
mm.
The chemical should not get drained off through the blow
down pipe. It should be so located that the chemical gets mixed well with the fresh
water before entering in to the down comers.
Continuous blow down
Pipe (CBD)
The boiler water is evaporated continuously and the relative
pure steam leaves the boiler drum. This mechanism is leads to concentration of boiler water with
more dissolved solids. Since the solubility of various
dissolved solids is
limited based on
the operating pressure,
it is necessary
to limit the concentration of dissolved solids in the boiler water. There
is always a carryover of dissolved solids of boiler water in to the steam. This is called vaporous carry
over. The percentage of carryover of each constituent is a
function of operating
pressure of the
boiler. Hence it is
necessary to limit
the concentration of boiler water with dissolved solids. Silica
is a bad water constituent that leads to hard deposits on turbine blades. The CBD pipe should be able to
draw the boiler water from the entire length steam drum. Any localized sampling
will lead to a wrong sample of the boiler water. It should blow down the high
TDS boiler water only. In should not lead to blow down of fresh water.
Drum Level Gauge
The exact level of the Steam Drum water
level is very important factor in the Power plant. Because if the drum level is
high, then the quantity of the steam production is less and it may affect the
turbine blades due to low quality of steam.
if drum level is
low then there is a chance of starvation of the boiler tube and it may change
the metallurgy of the tubes and there by the tube will be damaged, prematurely.
Hence
it is necessary to get the correct feedback from the field regarding drum
level.
For a Boiler operating up to a
pressure of 28 Kg/Cm2, use of only one gauge glass is recomended.but for the
power Boiler which is operating above 28 Kg/Cm2,an combination of the following
is used.
- Two gauge glass in
continue service and visible by the operator.
- Two independent remote transmitters
with one single gauge glass.
- One independent remote
transmitter and one single gauge glass(continuously in service) both of
the instrument must be continuously visible/Monitored by the operator from
control room.
Types of Level Gauge
There are mainly four types of
water level gauges
1.
Tubular
Type
2.
Reflex
Type
3.
Flat
Glass Type
4.
Ported
Type
Tubular type water level Gauge
glass limited to 17Kg/Cm2 operating pressure.
Reflex type can be used for the
pressure up to 24 Kg/Cm2.
Flat glass type can be used for
pressure up to 140 Kg/Cm2.
Ported Type gauge glass can be
used up to 210 Kg/Cm2.
Cyclone Box Chamber
When the
boiler is fitted
with cyclone separators,
all the water
steam mixture is
collected in a chamber. The mixture is made to pass
through multiple cyclones. The cyclones are mounted through
flange system to the cyclone box
chamber. The cyclones separate the water
and return to the water
space of the drum. The steam
leaves through the top chevron unit. The total system should meet the
following requirements.
Steam Purifier / Demister
Demister can be two stage Chevron
driers / demister / screen driers. Its
purpose is to trap the droplets and lead them back to drum water
Downcomer.
The water from the entire length of
the drum is allowed to pass through the down comer pipe and circulates through
the water wall panel through natural or forced circulation.
Intermittent Blow Down Pipe
It is apt to name it as emergency
drain valve through which the water level is brought down in case of
high level. In
low pressure boilers,
the intermittent blow
off valve was strategically
located for removal of settled sledges
generated by phosphates reaction with calcium and magnesium salts
good
ReplyDeleteHi Sir, could you explain more on the different in term of efficiency for baffle type and cyclone type steam separator. Usually in what circumstances cyclone is used? As far as I know cyclone type incur higher cost.
ReplyDeleteA convincing new look into the Great Pyramid as a device. Inspired by "Giza Power Plant" written by Christopher Dunn:
ReplyDelete3D Electromagnetic Great Pyramid Power Plant buy weed seeds
Boiler surely keeps your water supply get going. This article emphasis on human health and HVAC system services precautions. Love the article. Heating and Cooling Milton
ReplyDeleteA residential diaphragm gas meter is an essential device that accurately measures the gas consumption of a household. It is an effective way to track gas usage and prevent overbilling while ensuring the safety of the home and its occupants. Proper maintenance and regular inspection of the meter can help detect any potential issues and ensure its optimal performance.
ReplyDelete